How to read a Thymosin Alpha 1 certificate of analysis

Published Updated By the Thymosin Alpha Labs Research Team
Summary

A Thymosin Alpha 1 certificate of analysis ties results for purity, identity and net content to one lot, tested by a named laboratory on stated dates, with the chromatogram and mass spectrum as evidence. It establishes what was true of that sample when tested; it does not cover other lots, later dates or tests not listed.

A certificate of analysis (COA) is the laboratory's report on one sample. A useful one ties specific results to a specific lot, names the methods, dates the work and shows the raw evidence. This guide walks through each section of a Thymosin Alpha 1 certificate using the current lot as the example, then sets out what a COA establishes and what it does not.

The current Thymosin Alpha 1 lot, as an example

Certificate in progress. The current batch is with the testing laboratory. Its certificate of analysis will be published here, with purity, identity and net content, as soon as the report is issued. Current availability on Klow.bio.

Lot number

The lot number identifies the batch the sample came from, for example LOT123. It must match the lot printed on your vial label; a certificate for a different lot tells you nothing about your vial. Each Thymosin Alpha 1 lot has its own page in the COA archive, and any lot can be looked up at thymosinalpha.bio/verify.

Laboratory and reference numbers

  • Testing laboratory: who performed the analysis. Thymosin Alpha 1 certificates are issued by Freedom Diagnostics, an independent laboratory.
  • Client: who submitted the sample. Current certificates list Klow.bio / Klow Labs LLC, the company that operates Thymosin Alpha Labs.
  • Accession number and search code: the laboratory's own identifiers for the sample, used to look the result up with the lab.

To verify a Thymosin Alpha 1 certificate with the laboratory: Scan the Freedom Diagnostics QR code printed on the certificate, then search for klow.bio under the Company tab to view the laboratory record.

Testing dates

A certificate carries two dates: when the laboratory received the sample and when it reported the results. The results describe the sample as it was when tested. For a lyophilized peptide stored correctly, change over months is typically slow, but a certificate is not a measurement of the material on any later date.

Sample summary

A one-glance version of the results: product, purity, identity, net content and appearance, plus endotoxin and microbial results where those tests were run. Treat it as a summary; the detail is below it.

HPLC purity

Reported as a percentage by HPLC-UV. Check that the chromatogram is included and that the labeled main peak matches the product. A purity figure without a chromatogram cannot be checked. See HPLC analysis of Thymosin Alpha 1.

Identity

Reported as confirmed or not, with the method named. Common methods are LC-MS, which measures the main component's mass, and HPLC retention-time comparison with a reference standard. With LC-MS, labeled ions should match values calculated from the compound's molecular weight.3 Thymosin Alpha 1 certificates use liquid chromatography–mass spectrometry (LC-MS).

Net content

The measured milligrams of peptide in the tested vial. It is a different measurement from purity. See net content.

Endotoxin and microbial testing

Where run, endotoxin is reported by Limulus amebocyte lysate assay per USP <85> as pass or fail at a stated sensitivity, and microbial DNA by PCR.2 On Thymosin Alpha Labs lot pages, lots without these tests are marked "Not tested" rather than left blank.

Signature and disclaimer

The certificate is signed by the laboratory's principal chemist. The disclaimer states that results apply only to the tested sample and that sample handling can affect accuracy.

The certificate PDF and the lot record

For each Thymosin Alpha 1 lot, Thymosin Alpha Labs publishes two things: the laboratory's certificate as a PDF, and a lot record page on thymosinalpha.bio. The PDF is the laboratory's own document, including the chromatogram and mass spectrum images and the QR code for verification. The lot record reproduces every figure as readable text and adds the laboratory's reference numbers. The two should match exactly; if they ever don't, the laboratory's document is the authoritative one.

Reading the chromatogram yourself

  • Find the labeled main peak and check that its label matches the product.
  • Look at the baseline. It should be flat and low, with no large unlabeled peaks.
  • Note early signals near the start of the run. These usually elute close to the column's void time and are typically small polar species, not related peptides.
  • Check that the purity figure is plausible for what you see. A chromatogram with several large peaks cannot support a 99% purity figure.

Reading the mass spectrum yourself

  • Find the labeled ions and their charge states, written like [M+3H]3+.
  • Multiply each m/z by its charge, then subtract the protons (1.0073 each) and any adduct. The result should be close to the expected molecular weight: 3108.32 for Thymosin Alpha 1.
  • Expect small clusters rather than single lines. Natural isotopes spread each ion over several closely spaced peaks.

Comparing certificates across lots

Lot-to-lot comparison is useful when the same laboratory and methods are used. For Thymosin Alpha 1, all current certificates come from the same laboratory using the same HPLC and LC-MS methods, so results can be compared directly. Look for consistent retention time, the same principal ions and purity within the stated specification. Some lots carry additional tests, such as endotoxin and PCR, and others do not; a missing test is not a failed test, but it is also not a pass.

Red flags on any certificate

  • No lot number, or a lot number that doesn't match the vial.
  • No laboratory name or contact details.
  • A purity figure with no chromatogram.
  • Identity reported with no method named.
  • No dates, or dates that predate the material's production.
  • The same certificate used for several products or lots.
  • No way to confirm the result with the laboratory.

Common misreadings

  • "99.9% purity means 99.9% of the powder is peptide." No. Purity is relative to UV-detected material; water, salts and counterions are not counted. See peptide purity.
  • "Identity confirmed means the sequence was verified." Mass confirmation verifies molecular weight. Sequence order needs additional methods.
  • "A pass on endotoxin applies to the product." It applies to the lot and sample tested.
  • "The certificate shows the material today." It shows the sample on its test date.

What a COA establishes

  • That a specific sample, from a named lot, was tested by a named laboratory on stated dates.
  • The purity of that sample under the stated HPLC method.
  • That the main component's mass matches the expected compound.
  • The measured amount of peptide in the tested vial.
  • Endotoxin and microbial results, where those tests are listed.

What a COA does not establish

  • Results for any other lot.
  • Sequence order (mass confirmation alone cannot distinguish rearranged sequences).
  • Stability after the test date.
  • Results for tests that are not listed on it.
  • Suitability for any particular purpose.

Checklist for any peptide COA

  1. Does the lot number on the certificate match the lot on the vial?
  2. Is the testing laboratory named, with contact details you can check independently?
  3. Are the methods named for each result?
  4. Is the chromatogram included, not just a purity number?
  5. Is a mass spectrum included, and do the labeled ions match the compound's molecular weight?
  6. Are the received and reported dates shown?
  7. Is it clear which tests were not performed?
  8. Can the result be confirmed with the laboratory directly?

Validation of the underlying methods is outside what a single certificate can show; ICH Q2(R2) describes what a validated method should demonstrate.1

References

Published literature and guidance

  1. U.S. Food and Drug Administration. Q2(R2) Validation of Analytical Procedures: Guidance for Industry. March 2024. www.fda.gov/regulatory-information/search-fda-guidance-documents/q2r2-validation-analytical-procedures
  2. U.S. Food and Drug Administration. Pyrogen and Endotoxins Testing: Questions and Answers. Guidance for Industry, revised March 2026. www.fda.gov/regulatory-information/search-fda-guidance-documents/pyrogen-and-endotoxins-testing-questions-and-answers